REC: improve efficiency at forward region
- This MR is performed on the latest silicon tracker design
- Loose condition for current tracking algorithm, for simple particle
- Current values for p low to 5GeV at theta 10 degree, if want to lower momentum, need more loose
- For physical channels, need more check on fake track rate
- Note: grassroots solution need optimize tracker design and implement better track finding